Page | 8P: 419.542.7751 F: 419.5426690 800.782.761 nemcofoodequip.comInstallation GuideAlways ensure that the glass surface of the range is mounted FLUSH with the counter top. The exposededge of the glass is fragile and can be easily chipped or broken by side impact.If flush mounting is not feasible, you can purchase the optional Stainless Steel Trim Ring this allows youmake a simple cut-out in the counter top, and the Trim Ring supports the unit and protects the glassedge from damage.With either mounting method, seal around the unit (and Trim Ring) with silicone caulking to keep liquidsfrom penetrating and getting below the surface.If the units are mounted in a closed cabinet, you must ensure that there is adequate air flow for theunits. Each unit draws in cooling air from the back, and exhausts warm air from the front. In a closedcabinet you must provide adequate openings for both the intake and the exhaust air.