10 LoadRunner™ Series Installation & Service Manual3.3 Power Cable Connection to BatteryBrown wire to positiveFuseBlue wire to negativeFigure 3-8. Power Connection to Battery1. Wire the fuse (5A) to the brown wire.2. Connect the power cable to the battery.- Brown wire connects to positive terminal.- Blue wire connects to ground.3.4 Hydraulic Pressure TransducerThe hydraulic pressure transducer should be installed at the hydraulic control valve.Tee FittingReducing FittingTransducer Hydraulic ValveFigure 3-9. Install Hydraulic Pressure Transducer1. Remove the hose where the transducer is to be installed.2. Install a tee fitting to connect the hose to the hydraulic valve.3. Insert a reducer if required (9/16” straight thread with O-ring is required to fit the Rice Lake pressuretransducer) to the opening in the tee where the transducer is to be installed.4. Run the cable along the frame to the cable access hole in the cab. Wire-tie the cable to the frame.ImportantNote Allow for slack when fitting and securing hydraulic hose lines as these move during normal operation.Plan a transducer cabling route that has little or no risk of pinching, stretching or melting the cables.Use split loom on all exposed cable to protect in areas where damage could be an issue.