9PROGRAMMINGA Presco™ keypad connected to DTA1 or a PACDLrevision 4.0 or higher connected to DLOG is required toprogram the PAC2. To enable programming with a keypadthe PAC2 must first be put into program mode. This isaccomplished by pressing the program button located in thebottom centre of the PAC2 below the “PUSH TOPROGRAM” text. When the program mode is entered theLED above the program button in the PAC2 will light up.Pressing the program button again will take the PAC2 out ofprogram mode.The PAC2 will remain in program mode for a period of 5minutes after the button has been pressed. Each time thekeypad is used to enter information this time is extended to5 minutes from that time.The PAC2 can be forced to exit program mode from thekeypad by simply entering #99E.When the PAC2 is in program mode the green LED on anattached PRE keypad will flash at a rate of once per second(provided the PRE has been wired to DTA1 as shown in theBASIC KEYPAD WIRING diagram on page 7).IMPORTANT NOTES:1. The d shown in the programming sequences must bereplaced by a 1 for door 1 or 2 for door 2.2. When programming a new Management or User code thetwo steps must be done from devices connected to DTA1.i.e. you cannot open a user location using a keypadconnected to DTA1 and then enter the new user code on akeypad (or other Presco™ device) attached to DTA2.10KEYPAD RESPONSES• warble = successful programming operation finished.• 3 x 2 beeps = code memory location opened.• long beep = unsuccessful operation.• 1 short beep = valid Momentary or Toggle user codeentered to operate ELC relay (unlock door).• 2 short beeps = valid Toggle user code entered todeactivate ELC relay (lock door).• 5 short beeps = valid Management code entered.The expected response from the keypad is shown in thesquare brackets [] after each programming sequence.NOTE all keys in a sequence (up to and including the e)must be pressed within 10 seconds of each other. Ifincorrect keys are pressed wait 10 seconds and then enterthe sequence again.CLEAR ALL USER CODES.All the user codes memories (000 to 399) can be cleared bythe use of the following sequence.press #, 8, 7, 6, 5 & E. [warble]RESET ALL MEMORIES CODE.The PAC2 can be reset to factory defaults by the use of thefollowing sequence.WARNING: Using this code will delete all user codes, themanagement code and reset memories 80 to 89 back totheir default settings.To reset the PAC2 to factory defaults…press #, 8, 7, 6, 5, 4, 3, 2, 1, & E. [warble]11BASIC SETUP SEQUENCE1/ Select ELC RELAY TYPE (Currently N/O). [Memory82, page 12]2/ Select EGRESS switch type (Currently N/O). [Memory81, page 12]3/ Set ELC OPERATE TIME (Currently 10 seconds).[Memory 83, page 13]4/ Enable/Disable DOOR INPUT (Currently disabled).[Memory 84, page 13]5/ Set Door Open Too Long time (Currently 60 seconds).[Memory 85, page 13]6/ Enable/Disable DOOR FORCED OPEN DETECTION(Currently enabled). [Memory 86, page 14]7/ Enable/Disable AUTOMATIC RELOCK (Currentlyenabled). [Memory 80, page 12]8/ Enable/Disable 1 MINUTE LOCKOUT (Currentlydisabled). [Memory 87, page 14]9/ Enable/Disable USE TWO MOMENTARY CODES(Currently disabled). [Memory 88, page 14]10/ Set TWO CODES TIMING, if enabled in step 9 above(Currently 60 seconds). [Memory 89, page 15]11/ Program MANAGEMENT CODE. [Memory 9, page 16]12/ Program USER CODES. [Memories 000 to 399,page 17]12Automatic Relock. Memory 80(Factory Default: Automatic Relock is enabled)Disabling the Automatic Relock function prevents the ELCrelay output from deactivating 1 second after the door isopened. This function is only valid when the DOOR input isbeing used.To disable the Automatic Relock function…press *, 8, 0, d, 0, & E. [warble]To enable the Automatic Relock function…press *, 8, 0, d, 1, & E. [warble]EGRESS Switch Type. Memory 81(Factory Default: Normally Open EGRESS device)Either a normally open or normally closed EGRESS switchsetting may be selected.To set the EGRESS switch input to normally closed…press *, 8, 1, d, 1, & E. [warble]To set the EGRESS switch input to normally open…press *, 8, 1, d, 0, & E. [warble]ELC Relay Type. Memory 82.(Factory Default: ELC is Normally Open)The electronic latch control (ELC) relay can be set tooperate as either Normally Open (NO) for fail secure orNormally Closed (NC) for fail safe.To set the ELC relay type to normally closed…press *, 8, 2, d, 1, & E. [warble]To set the ELC relay type to normally open…press *, 8, 2, d, 0, & E. [warble] |
Related manuals for Nidac 2 Series
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine