Niigata seiki WCDI-10D Instruction Manual
TROUBLESHOOTINGMEASUREMENTOPERATIONMeasure absolute dimension of workpieceABSOLUTE MODE (ABS)SPECIFICATIONSABS/SETMIN CALZERO/ONABS/SETMIN CALZERO/ONABSOOASSEMBLYACCESSORIESABS/SETMIN CALZERO/ONABSOOABS/SETMIN CALZERO/ONABSOOABS/SETMIN CALZERO/ONABSOO ABS/SETMIN CALZERO/ONOONiigata Seiki Co., Ltd.5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055Tel. : +81-256-33-5522 Fax. : +81-256-33-5518MAIL intl.sales@niigataseiki.co.jpURL http://www.niigataseiki.co.jpAdjacent errorDIGITAL BORE GAUGE Model No. WCDI-10D/ WCDI-18D <combined>AccessoriesIncluding supplied Digital GaugeNot including quantization error ( 1 count)Loosen the Clamp Screw and insertthe Digital Indicator into the gaugebody. Tighten the Clamp Screw tosecure.After attaching, press the [ZERO/ON]Button on the Digital Indicator to turn onpower. Confirm that the displayedreading changes by gently squeezing themeasurement head. If necessary, adjustthe depth that the Digital Indicator isinserted into the gauge body.Select the Extension Rod, washer (WCDI-18Donly) for the desiredmeasurement range.PART IDENTIFICATIONWCDI - 10D6 - 101250 .7WCDI - 18D10 - 180 . 0 0 231250 . 0 0 230 . 90 6.0WCDI-18DWCDI-10DSpannerSpannerNut1. Use the Spanner to loosen theNut at the bottom ofMeasurement Head.2. Install the Extension Rod andtighten.Attach the Extension Rod,Washer to the bottom of theMeasurement Head and tightenwith the Spanner.Ex. Rod8.5mmWasher 0.5mmWCDI-18D onlyExtension RodWCDI-10D WCDI-18D SpannerWCDI-10D WCDI-18DNOTICEINSERTING REPLACING BATTERYAUTO OFF DELAYUse only CR2032 type lithiumbutton cell.NOTICEAuto Off Delay2 6 5 3 0 0Press and hold the [ZERO/ON] Button to turn power OFF.Press and hold [ABS/SET] and [ZERO/ON] Buttons at thesame time.When ----- is displayed, release the [ZERO/ON] Button,then release the [ABS/SET] Button in that sequence.The Auto Off Delay time will be displayed. Press [ABS/SET]to change.Each press of the [ABS/SET] Button will change the delayby 1/2 hr. (30 min.) from 0 to 6 hr.Press [ZERO/ON] when done and display will return to themeasurement screen.Once set, the delay time is saved even when power is OFF.Thank you for purchasing the Digital Bore Gauge.Please read this manual thoroughly before use for proper operation.Instruction ManualThis is a precision instrument, handle with care.Do not disassemble or modify.Keep instrument away from water and oil.Use only with supplied Extension Rods and Washer.Keep instrument away from direct sunlight and high temperaturessuch as in a car, or near a stove or heat source.After use, remove any dirt or cutting chips and apply rustpreventative oil to Extension Rod and Washer. When not in usestore in supplied storage case.This product is for measuring inside diameter; use only as directed.Improper use may cause accident or injury.Avoid using in high electric fields, such as near fluorescent lights orswitching power supplies. Electrical interference may causeincorrect readings.Pull out the case from the twoside edges to remove. Insertbattery with (+) side facingdown.BatteryCaseBatteryCR20321 Not Used2 "0.01" indicates the resolution ofthe display's digital bar graph.The bar graph display willchange with each 0.01mmchange in the measured value.Spanners shown in drawingabove vary slightly inappearance, but function willbe same.Ex. WCDI-10D set to 8.5mmEx. WCDI-18D set to 14.5mmLength below Handle:100mmExtensionRodMeasurementHead GuideProbeTipProbeTip[ZERO/ON]Button[CAL] ButtonHandleCapLength belowHandle:12[MIN]Button[ABS/SET]ButtonClampScrewGauge(Digital Indicator)LCD DisplayExtensionRodMeasurementHead50mmMeasuring RangeResolutionWide range accuracyRepeatabilitySingle Stroke RangeWeightModel No.hExtension RodsWCDI - 10D 6 6.5 7 7.5 8 8.5 9 9.5 10mm 9 piecesWCDI - 18D 10 11 12 13 14 15 16 17 18mm 9 piecesWasher 0.5mm WCDI-18D onlySpanner 1xBattery CR2032 Lithium button cell, 1x for testEx. Rod14mmWasher0.5mmClampScrewINSERTShaftFig.1 Fig.2 Fig.3Fig.4Fig.5Fig.6For accurate measurements, follow the procedure described below.In cross section perpendicular to the axis of the bore, as shown in Figure 1, position the gauge along diameter . This is themaximum distance, and at this point the Indicator will read the maximum value. The Guide will automatically position the MeasurementHead to diameter when inserted.WCDI-10D does not have a guide on the Measurement Head so please manually position at this maximum value.In cross section parallel to the axis of the bore through diameter , position the indicator to minimize the distance . (Figure 2)In this position the Indicator will read the minimum value. This position must be manually determined by pivoting the Gauge as shownin Figure 3 while watching the Indicator to find the minimum value.Before use, please make sure the Measurement Head components are not loose and tighten if necessary.Clean the Measurement Head and the ID of a Ring Gauge Standard using parts cleaner or cleaning solution.Press the [ZERO/ON] Button to turn on power. A long press to the [ZERO/ON] Button will turn power off.Turn on power. If or symbols are displayed on the LCD,press the [MIN] Button to turn off. If ABS is displayed press the[ABS/SET] Button to turn off.Insert the Measurement Head into the Ring Gauge Standard and press[MIN] Button to put the Indicator into minimum-mode. Slowly pivot thegauge (Figure 3) to display the minimum value.Remove the gauge from the Ring Gauge and press the [CAL] Button untilOK is displayed.Preparation for measurement is now complete.Put the gauge into the workpiece to be measured, and pivot the gaugeslowly. (Figure 3) The LCD will display the difference between themeasured workpiece and the calibration standard. (Figure 6)Press the [ON/ZERO] Button momentarily to reset display in preparationto measure the next workpiece.Turn on power. If the or symbols are displayed on the LCD, press the [MIN] Button to turn off.Adjust the SET value of the Bore Gauge to match the ID of the Ring Gauge Standard. Press and hold the [ABS/SET] Button untilSET blinks on the display.Continue holding the [ABS/SET] Button and the display character to the left will blink. Use a short press of the [ABS/SET] Button tochange the value, and a long press to change the character being modified. Repeat this process to enter the dimension of the RingGauge Standard on the LCD display. (Figure 4)When the value is entered the flashing position will return to SET . A shortpress of the [ABS/SET] Button to turn off the flashing.Insert the Measurement Head into the Ring Gauge Standard and press the[MIN] Button to put the Indicator into minimum-mode. Slowly pivot thegauge (Figure 3) to display the minimum value.Remove the gauge from the Ring Gauge and press the [CAL] Button untilOK is displayed.Preparation for measurement is now complete.Put the gauge into the workpiece to be measured, and pivot the gaugeslowly. (Figure 3) The LCD will display the measured value. (Figure 5)Press the [ON/ZERO] Button momentarily to reset display in preparationto measure the next workpiece.Difference between workpiece and referenceCOMPARATIVE MEASUREMENTSERROR CORRECTIVE ACTION If problem persists, or if you have anyquestions, please contact distributor.Please note, manufacturer is unable torespond to inquires or provide servicedirectly. Please contact distributor.LCD does not displayDisplayed value is unstableDisplay is not clearCycle power by removing andreplacing battery.Replace battery with new one.Work-pieceWork-pieceDiff. between Work-piece and ReferenceSet to matchWorkpiece I.D. valueRing GaugeStandard |
Related manuals for Niigata seiki WCDI-10D
Niigata seiki WCDI-50D Instruction Manual
Niigata seiki WCDI-6 Instruction Manual
Niigata seiki WCDI-35 Instruction Manual
Niigata seiki WCDI-6D Instruction Manual
Niigata seiki WCDI-50 Instruction Manual
Niigata seiki WCDI-35D Instruction Manual
Niigata seiki CDI-18D Instruction Manual
Niigata seiki CDI-50 Instruction Manual
Niigata seiki KMC-1001 Instruction Manual
Niigata seiki DT-150 Instruction Manual
manualsdatabase
Your AI-powered manual search engine