5ATTIX 30-50 H/MCAUTIONDamage due to unsuitable mains voltage.The appliance can be damaged as a result of being connectedto an unsuitable mains voltage.Ensure that the voltage shown on the rating plate corre-1.sponds to the voltage of the local mains power supply.Picking up liquids CAUTIONPicking up liquids.Do not pick up flammable liquids.Before liquids are picked up, always remove the filter bag/1.waste bag and check that the float 1) or the water level lim-it 1) works properly.The use of a separate filter element or filter screen is rec-2.ommended.If foam appears, stop work immediately and empty the3.tank.Hazardous materials WARNINGHazardous materials.Vacuuming up hazardous materials can lead to serious oreven fatal injuriesThe following materials must not be picked up by the1.vacuum cleaner:hot materials (burning cigarettes, hot ash, etc.)-flammable, explosive, aggressive liquids (e.g. petrol,-solvents, acids, alkalis, etc.)flammable, explosive dust (e.g. magnesium or alumin--ium dust, etc.)Using the vacuum cleaner forasbestos abatement work WARNINGTo pick up materials containing asbestos:ATTIX 30-XH and ATTIX 50-XH1. can be used for pickingup asbestos.The hose diameter and the setting for the suction hose2.diameter must be the same.Use the closable plastic sack to ensure dust-free transportof the vacuum cleaner and contaminated parts (hose, handpipe, nozzles, etc.). Once the asbestos vacuum cleanerhas been used in an exclusion area as definedin TRGS 519, it should no longer be used in so-called“white” areas. Exceptions are only permitted if the asbestoscleaner has previously been completely decontaminatedby a specialist as specified in TRGS 519 No. 2.7(e.g. not only the outer case but also, for example, thecooling air rooms, the installation rooms for electricalsupplies, the supplies themselves, etc.). A written reportmust be made by a specialist and signed by him.When dust removers are used, the rate at which air isexchanged in the room must be adequate if the exhaustair from the vacuum cleaner is blown into the room (pleaseobserve regulations valid in your country). If using exhaustair collector, use a hose with a length of max. 4 m and anominal diameter of max. 50mm.1) Optional accessories / Option depending on model