12 SCRUBTEC 343E 909 6315 000(4)2009-11 AENGLISH USER MANUALMACHINE TRANSPORT/PARKINGTo transport/park the machine, proceed as follows.Turn the brush/pad-holder switch and the vacuum system switch (52 and 53) to “0”.1.Disconnect the power supply cable (21) from the electrical mains and place it on the holder.2.Lift the squeegee with the lever (19).3.Grasp the handlebar (2) and slightly lower it until the rear wheel (7) comes into contact with the floor (Fig. 2). While holding the4.machine in this position, drive it to the transport/parking area.In order not to drag the brush/pad on the floor and leave wet marks, when finishing working, remove the brush/pad-holder from5.the deck by using the release device (see the procedure in After Using The Machine paragraph), then place it on the support(25).Figure 2S310234TANK EMPTYINGAn automatic float shut-off system (36) turns off the vacuum system when the recovery tank (26) is full.The vacuum system shutdown, due to the recovery tank filling, is signalled by an increase in the vacuum system motor noise,moreover the floor is not dried.CAUTION!If the vacuum system turns off accidentally (for example, when the fl oat is activated because of a suddenmachine movement), to resume the operation: turn off the vacuum system by pressing the switch (53), thenopen the cover (6) and check that the float inside the grid (36) has gone down to the water level. Then close thecover (6) and turn on the vacuum system by pressing the switch (53).When the recovery tank (26) is full, empty it according to the following procedure.Recovery tank emptyingStart the machine by pressing the brush/pad-holder and vacuum system switches (52 and 53).1.Disconnect the power supply cable (21) from the electrical mains and place it on the holder.2.Lift the squeegee with the lever (19).3.Drive the machine to the appointed disposal area.4.Insert the positioning pin (24) and lift the brush/pad-holder by engaging the transport/parking device (23a).5.Empty the recovery tank (26) with the drain hose (16).6.Then, rinse the tank with clean water.Solution tank emptyingPerform steps 1 to 4.Empty the solution tank (27) by using the drain valve (18).7.Then, rinse the tank with clean water.8.