-24- FORM NO. 70935A Nilfi sk ALTO Operator's Manual - SCRUBTEC 770 / 784 / 795Figure #21Figure #22Figure #23B AMAINTENANCEDo These Procedures When You End Your Work1. Drain the solution tank (Figure #21, item A) and the recovery tank(Figure #21, item B). To drain the tanks , follow this procedure:a. Turn the key switch “OFF”.b. Remove the drain hose from the back of the machine.c. Put the end of the hose over a drain or bucket.d. Recovery Tank:Turn the valve housing to the left (see figure #22). To open thevalve completely, turn the housing fully to the left and pull thehousing off of the valve.Solution Tank:When hose is lowered below water level, the water will drain (seefigure 23).2. Flush the tanks. To flush the tanks, put clean water in the tank throughthe opening on top of the tank.3. If a tank or drain hose has an obstruction, use a high pressure waterhose to flush the tank or hose. Put the water hose into the drain hose.4. Leave the tanks and the drain valves open to dry in the air.5. Check the squeegee blade. Use a cloth to clean the squeegee blade. Ifthe squeegee blade is damaged or worn, turn or replace the blade.6. Check and clean the recovery lid gasket. Use a mild cleaning solutionand rinse the parts in clean water.Check the batteries and add distilled water as needed. The correct level iswithin 1/4 inch of the bottom of the tube in each cell.CAUTION!Tap water may contain contaminants that will damage batteries.Batteries must be re-filled with distilled water only.WARNING!Lead acid batteries generate gases which can cause an explosion.NO SMOKING. Always wear eye protection and protective clothingwhen working near batteries.Use a clean cloth and wipe the surface of the machine.Charge the batteries. See the instruction in the section of this book called“How To Charge The Batteries”.