Squeegee System 76Service Manual – Focus II / Scrubtec R6 Rider AutoscrubberSqueegee Lift Actuator1. Before turning off the machine, go into the ServiceTest Mode described on page 22, and lowerthe squeegee enough to release tension from thelifting cable.2. Turn off the machine and disconnect the batteryto prevent the squeegee lift from inadvertentlybeing activated.3. Remove the Recovery Tank described on page52.4. For easier access, you may wish to remove theScrub Deck described on page 59.5. Remove the C-clip (11) from the rear guide pin(12), and remove the pin and lift cable (13).6. Disconnect the motor cable connector (14).7. Remove the cotter key (15) from the front guidepin (16), and remove the pin.8. Slide the lift actuator (17) out toward the front ofthe machine.Note: If the actuator is being removed formaintenance that will not require readjustingthe limit positions, then take care not to rotatethe nut (18) with respect to the gear housing(17).9. For a new actuator or if the nut was repositionedwith respect to the gear housing, perform theActuator Limit Adjustment described on page73.10. Reinstall the actuator on the machine by reversing the procedure steps.SpecificationsParameter RangeSqueegee Lift Actuator Amperage • Raising = 2.2 - 3.4 A• Lowering = 2.3 - 2.6 A1112131814151617