34 - FORM NO. 56043094 / Captor™ 4300, 4800, 5400 / CR 1100, 1200, 1400SWEEPING SYSTEMFRONTBAAWAYAZAXBB1/2"(13mm)* "MAIN BROOM LIFT CABLE REPLACEMENT (CONTINUED)8 Start the engine and lower the scrub deck and then remove the rear engine panel to access the exhaust system.CAUTION!Allow a hot exhaust system to cool before disassembling.9 See Figure 10. Remove the (2) item (AW) Exhaust Flange Bolts and separate the exhaust pipe inlet tubing Connection (AX). Next removethe Muffler Clamp (AY) and separate the outlet exhaust Tube (AZ) from the muffler.10 From underneath the machine remove the (3) item (BA) Screws that secure the muffler assembly to the chassis and move it to the side to gainaccess to the broom lift cable Hanger Weldment (BB). Then remove the cable ball joint end from the broom hanger mount.11 Loosen the cable casing anchor jam nuts and pull the cable from its mounting bracket. Note: Also remove the jam nuts from the cable casing.12 Remove the A1 controller access panel (4 screws) located in the driver’s compartment below the solution lever.13 Remove the A1 control box to help route the cable through the machine chassis.14 Remove all the jam nuts from the new cable then attach securely the new cable to the old cable at the lower broom hanger.15 Remove the cable by pulling on the original cable from the operator’s handle. Guide the old cable out and at the same time fish the new cableup through the frame and control box opening and reattach at the operator’s handle.16 Reattach both cable ends and adjust the cable’s anchor connector ends to obtain the correct broom raise/lower operational limits. See Figure11 for approximate cable anchor mounting dimensions.17 Reinstall all the previously removed components and reset the correct broom pattern width of between 2-3 inches (50-75mm).FIGURE 10FIGURE 11