INSTRUCTIONS FOR USE33015122(1)2006-02 9(*) If the machine is to be used at ambient temperatures below +50°F (+10°C), the oil should be replaced with equivalent oilhaving a viscosity of 32 cSt. For temperatures below +32°F (0°C), use oil with lower viscosity.ENVIRONMENTAL CONDITIONS– In the environment where the machine operates, there must not be any danger of explosion.– To avoid inhaling exhaust gas, the machine must be used only where there is a proper air change.– The machine operates correctly (*) in the following environmental conditions:– Temperature: +14°F to +104°F (-10°C to +40°C)– Humidity: 30% to 95%(*) When using the sweeper at a temperature between +14°F e +32°F (-10°C and 0°C) the dust control system cannot beused; moreover the water tanks and the dust control system itself must be empty.Diesel engine data ValuesMake LombardiniType LDW 1603BZCylinders 3Maximum speed 2,600 rpmMaximum working speed 2,200 rpmMaximum power at 2,600 rpm 24.0 kW (32.18 hp)Idle speed 900 rpmEngine coolant 50% of AGIP antifreezeand 50% of waterNOTEFor other diesel engine data/values, see the relevant Manual.Refuelling data ValuesFuel tank capacity 7.9 US gal (30 liters)Hydraulic system oil tank capacity 12.6 US gal (48 liters)Electrical system data ValuesSystem voltage 12 VStarting battery 12 V – 80 AhHydraulic system data ValuesTotal hydraulic system oil capacity 17.1 US gal (65 liters)Maximum drive system pressure 3,626 psi (250 Bar)Maximum service system pressure 1,740/2,900 psi (120/200 Bar)Hydraulic system oil viscosity (at ambient temperature above +50°F (+10°C)) (*) 68 cStClimate control system data (optional) ValuesGas type Reclin 134aGas quantity 1.76 lb (0.8 kg)https://harrissupplyind.com - To Order Parts Call 608-268-8080