INSTRUCTIONS FOR USE ENGLISH9100001614 - SC250, Scrubtec 334 1507/2016RECOVERY TANK AND COVER CLEANING1. Lift the tanks container (13) from the machine body usingthe handle (15).2. Remove the cover (A, Fig. 11) and clean it with hot water.3. 5HPRYHWKHVXFWLRQJULG % DORQJZLWKWKHÀRDWDQGFOHDQthem thoroughly.4. If necessary, remove the body (C), then clean with careand reinstall.5. Check the recovery tank cover gasket (D) for integrity.NOTEThe gasket (D) creates the vacuum in the tank that isnecessary to vacuum up the recovery water.If necessary, replace the gasket (D) by removing it from itshousing on the cover. When assembling the new gasket,LQVWDOOWKHMRLQW ( LQWKHDUHDVKRZQLQWKH¿JXUH6. Check the air duct gasket (C) conditions. If necessary,replace the gasket.7. Clean the tank compartment (G) with water and detergent,then rinse carefully.8. Check that the seating surface (H) of the gasket (D) isclean and adequate for the gasket itself.9. Reassemble the components.10. If necessary wash the solution tank with clean water.AGHDECFBFigure 11P100942CLEANING OF THE SOLUTION FILTER, AIRFILTER, GASKETS AND RECOVERY WATERDUCT1. Remove the tanks container (13) from the machine bodyusing the handle (15).2. Remove the rubber gasket (A, Fig. 12), then remove the¿OWHUVWUDLQHU % 3. Clean them and reinstall in the housing (C).4. 5HPRYHWKHDLU¿OWHU ' DQGFOHDQLW5. 5H¿WWKH¿OWHULQWKHKRXVLQJRIWKHJDVNHW ( NOTEThe gaskets (E) and (F) create vacuum in the systemthat is necessary for vacuuming the recovery water.6. Check and clean the gasket (E) of the vacuum systemmotor.7. Check and clean the recovery water duct gasket (F).8. Rinse the inside of the duct (G) with water.FABCDEGFigure 12P100943