36Technical data, machine Supreme 100 Supreme 150Performer 150Supreme 250Performer 250 Supreme LCDHeight 427 mm 800 mm 801 mm 802 mmWidth with handles 370 mm 370 mm 370 mm 370 mmLength with bracket 400 mm 400 mm 400 mm 400 mmMotor 1300 W 1550 W 1700 W 1700 WFuse 10 A 10 A 10 A 10 AWeight 5 kg 6.5 kg 6.5 kg 6.5 kgSound output 66 dB 66 dB 66 dB 66 dBCapacity of dust container - 25 l 25 l 25 lCapacity when using the bag 10 I 14 l 14 l 14 lMax suction power motor 650 Airwatt 720 Airwatt 735 Airwatt 735 AirwattMax suction power* 460 W 490 W 510 W 510 WMax air flow* 50 l/s 53 l/s 54 l/s 54 l/sMax vacuum* 21 kPa 30 kPa 30 kPa 30 kPaRadio remote control X X X XPanel with operation status XTechnical data, handle LED LCDRadio frequency 433 MHzFunction On/off, power regulation 5 steps, LEDindication of operation statusOn/off, power regulation 5 steps, LCDindication of operation statusLifetime of battery 3 years 3 yearsBattery type, qty. 1.5 V AAA, 2 pcsRange of operation Max 50 metres.*Measured on the suction unitThese appliances conform with EU Instructions 2004/108/EC, 2006/95/EC.1.1 Technical data1 Important safety precautionsTo reduce the risk of fire, electric shock or injury,read all safety precautions and warning text carefullybefore using the machine.• This central vacuum cleaner is solely intended for dryvacuuming indoors.• This central vacuum cleaner is not intended to be in-stalled outdoors.• Never vacuum without a filter installed.• Do not vacuum up liquids. Do not use the machine in wetsurroundings.• Do not vacuum up embers or burning objects such ascigarettes, matchsticks, hot ash or flammable liquid orgas.• Do not vacuum in areas where flammable liquids or gasesmay be present.• Unplug the machine before changing the filter or bag andbefore doing any maintenance work.• Always unplug the machine by pulling on the plug, not thepower cord.• The wall socket and plug must be positioned so that theyare clearly visible.• Do not vacuum up sharp objects such as broken glass orneedles that could puncture the bag and damage the mo-tor.• Be particularly careful not to pick up objects that couldblock the hose/pipe system, such as pencils, toy bricksand small plastic bags.• Follow the operating instructions carefully. Servicingand repairs should only be carried out by an authorisedworkshop. Use only original parts and accessories asrecommended by the supplier. Never attempt to modifythe machine yourself.• Do not use the central vacuum cleaner if the power cordis damaged. The central vacuum cleaner is fitted with aspecial type of power cord that must be replaced with acord of the same type if it is damaged. A power cord ofthis type can be obtained from a service contact. To avoidany risk, this power cord should be replaced by a qualifedexpert.• This appliance is not intended for use by young personsor infirm persons without supervision unless they havebeen adequately supervised by a responsible person toensure that they can use the appliance safely.• The central vacuum cleaner must not be used as a toy.• The installation of the exhaust pipes must be done, sothat no water or condensation will get into the installationsystem.The central vacuum cleaner must never be used tovacuum up contaminated dust or cement dust.