Nokia N97 miniRM-553 / RM-555Service Manual Level 1&225 Confidential Copyright © 2009 NOKIA All rights reserved Version 1.0 ISSUE 112.3 TroubleshootingWhen touching the points on the phone UI, there is a 30 second timeout. If this expires withoutreceiving 3 points, the procedure will abort. Simply press “Retry” to start again.If the phone connection to Phoenix is disrupted (e.g. cable is disconnected), the recalibrationwill stop. Make sure the connections are correct, and restart the calibration procedure.For verification failure issues: Send/End keys not working Touch panel is not working Drawn lines are not following the tip of the SS-93/stylus There are large “dead” areas where lines cannot be drawn Restart Phoenix and retry the calibration again. If verification continues to fail, contact your next level of support.