10When installing the UC4+sensors (E02), start with thesmallest serial number on the lefthand side proceeding to thelargest serial number on the righthand side (Figure 9).5. Sensor cables should run through themounting bracket tube and then behindthe member the bracket is mountedonto. Cable-tie the connector in place.The cable must not be allowed to hangbelow the boom (Figure 6).Figure 6: Another AcceptableMountingAvoid mounting sensors inlocations where they may readfrom parts of the boom as shownin Figure 7.Figure 7: Poor Mounting(Sensor reading off boom)General mounting rules for UC4+ultrasonic wing sensors:a) In its lowest position, the sensor mouthmust be 9 inches or more from theground.b) The bottom of the sensor must be atleast 9 inches in front of the spraynozzles.c) The bottom of the sensor must be atleast 9 inches above the spray nozzles.d) Ensure that there are no obstructionswithin a 12-inch diameter circleprojected directly below the center ofthe sensor.e) The sensor should be approximatelyvertical at normal operating heights.Figure 8: Sensor Mounting GuidelinesA BBDCUltrasonicAcoustic Cone