Lighting Instructions - Gas OperationWARNING: Hazardous Vapors. Holding the gas valve (C) in without flame ignition will cause gas tobuild-up in the burner area and can result in severe personal injury, property damage, or death. Donot hold the gas valve in for more than 30 seconds. If the flame is not indicated within this time,turn the mode selector knob to OFF, wait 2 minutes, and retry. If the flame still will not ignite, shutthe refrigerator off and contact a service repair technician.To light the refrigerator:1. Turn on the gas supply to the refrigerator.2. Set the thermostat (B) to it’s maximum setting.3. Push and turn the "Elec-Off-Gas" (C) knob counter-clockwiseto the "Gas" position.4. Hold the control knob (C) in and push the igniter (A) repeatedlyuntil the gas is lit at the burner.5. When the flame indicator (D) starts to move, stop pushing theigniter. Continue to hold the control knob in for approximately 5seconds, then release. The flame indicator needle should re-main in the green area indicating the flame is present at theburner. If not, repeat steps 4 and 5.The flame should ignite within 10 seconds. On initial refrigeratorStart-Up, it may take longer than 10 seconds to allow air to bepurged from the propane gas supply line.6. Set thermostat control (B) to desired setting after initial cooldown.Shutdown - All Modes1. Push and turn the "Elec-Off-Gas" (C) control knob to the "Off"position.Warranty Time Allowance• Norcold will pay the time allowance multiplied by the service facility prevailing shop labor rate.• The time allowances which follow include diagnostic times include defective part replacement and gas leaktest times (when applicable).• A gas leak test is required when gas connections, either the main gas supply line to the refrigerator or therefrigerator gas components have been disconnected.Warranty Time Allowance ChartReplacement Part Time allowance Replacement Part Time AllowanceBurner .5 HR. Flame Meter .6 HR.Combination Control 1.0 HR. Heater (AC) .6 HR.Cooling Unit 1.5 HR. Thermocouple Adapter .6 HR.Door Handle (parts of) .3 HR. Orifice/Orifice Gasket .5 HR.Electrode (Ignition) .5 HR. Spark Ignitor (Piezo) .6 HRFlame Indicator Light .3 HR. Thermocouple .6 HR.A B C DFigure 7Start-Up Instructions - AC Operation1. Make certain 110 volts AC are avail-able to the refrigerator.2. Set thermostat to maximum setting.3. Push and turn "Elec-Off-Gas" controlknob clockwise to "Elec". Upon re-lease, the knob will move outward,indicating the control is locked intoelectric operation.Lighting and Start Up Instructions5