10N3104, N3141, N3150 ModelsError Code Tests, cont’d.STARTReplace powercontrol board andLCD display.YesIs unit productiondate prior to Jan. 4,2013?Replace powercontrol board.NoError Code 2Burner controlmodule sensesincorrectfeedbackBe sure you have followed the "Diag-nostic Pre-Checks" before continuing.Once the problem is corrected, youMUST power the refrigerator off andon to clear the fault code display.NOTICEBe sure you have followed the "Diagnostic Pre-Checks" before continuing.Once the problem is corrected, youMUST power the refrigerator off andon to clear the fault code display.NOTICEError Code 3Gas lockoutIs there fuel in the propane tank?Is there an audible click or visualspark at the gas valve?STARTDoes the gap between the electrodeand burner measure approximately3/16"?Is electrode or electrode connectiondamaged?Check gas pressure. Does the WCmeasure 11<12"?Repair gas supply.Turn unit off and on.Is there a spark at the gas valve?Replenish gas supply.Adjust the electrode gap to 3/16"Problem solved?Is gas valve open during ignitionspark?Does the burner orifice look clean; isthe flame dense and blue?Replace power controlboard and LCD display.Is unit production date prior toJan. 4, 2013?Replace power controlboard.Clean burner and orifice. Ifnecessary, replace burner.NoYesNoYesYesNoYesNoYesNoYesReplace gas valve.YesNoNo Yes NoNoRepair electrode connection.Problem solved?YesNoNo