www.norcold.com/cda12 Refrigerator Service ManualN6XX/N8XX ModelsF/no FL Fault Code – Burner failed to ignite or reigniteAir gap1/8 to 3/16inch?Burnerclean?Before beginning this procedure make sure: RV LP gas tank valve is open. Refrigerator solenoid gas valve manual shutoff is open. LP gas pressure at the solenoid gas valve pressure tap is 10.5.Models and fault indicator displayed.ONGASN62X/N82XLP GASACAUTOClean and service burner.See page 30.NOYESCheck that electrode tip-to-burner air gap is correct.NO Set electrode-to-burner air gap1/8 to 3/16 inch.YESContinuity?Check spark/sense electrodeassembly for continuity.NO Replace spark/sense electrodeassembly.Voltage?YESCheck voltage across powerboard terminals GV andGV GND.NO Replace power board.Continuity?YESCheck gas valve solenoidwires for continuity.NO Replace gas valve wires.YESCheck gas valve solenoidresistance..NO Replace gas valve.79 to 85 Ω?Check burner.YES Faulty or obstructed gas valve.Replace gas valve.N61X/N81XN64X/N84XDisplayAlternatingAudibleAlarmGAS LEDflashingconstantly