CLEO COMBI.28 8192000 Rev.08 – EN1) Open the lateral access hatch to the mechanical parts (L Picture 9); if the lever (C) is already in position P(PELLET) go to point 3);2) With the use of the poker in the position D, lift the latch and decontrol the lever (C) push it toward the front side ofthe stoves in the position marked with the letter P and stop itwith the latch (D) in the position 2 shown in Figure 2; cast irongrate (G)in upright position;3) check that the hatch of the pellet feeding tank (S) is closedand locked using the handle (B);4) close the lateral access door(L) to the mechanical parts.ATTENTION: before lighting, the stove must be as in theoriginal state, i.e. with the side door and the tank lid closedusing the handle.The lighting procedure is manual and envisions the followingpoints:IMPORTANT: for correct and uniform lighting, it is necessary touse a pair of fire-lighter cubes (Picture 10 pos.1 pos.2).• Check that the register of the primary air is completelyopen;• Open the upper door;• Place the relevant supplied chute (Picture 10 pos.A) onthe grate and in the rear edge of the burner caps (pos.1pos.2);• Place a fire-lighter cube on the chute, light it and make itslide inside the burner;• When the two cubes have been lit in pos.1 and pos.2,remove the chute and close the fire door.ATTENTION: do not use any inflammable liquids for lighting.When lighting has taken place, the user can adjust the heating power through the primary air register (R) from theminimum power (register towards left) to the maximum power (register towards right completely open).ATTENTION:• The lid of the pellet container must always be closed. It must onlybe opened during the fuel feeding phase.• The bags of pellets must be kept at least 1.5 metres from thestove.• Do not allow the bag of pellets to come into contact with theboiling hot stove during the filling phase10. NORMAL FUNCTIONINGDuring normal stove functioning of the pellet stove, the cinders must beshaken to prevent stratification of the ash. (see par. 14.3 – 14.4)The appliances with automatic door closure (type 1) must function, forsafety reasons, with the hearth door closed (except for the fuel feedingphase or removal of ash).The appliances with constructive system type 2 must be connected totheir own flue. The operating with open door is allowed under supervision.IMPORTANT: For safety reasons, the hearth door can only beopened when feeding the fuel. The hearth must remain closedduring functioning and standstill periods.The nominal calorific value of the stove is equal to 6.4kw-wood / 6kw-pellet and is reached with minimum draught (depression) of 12 Pa (= 1.2mm of water column).Using the registers ( R ) on the stove face (Picture 1) regulate the emission of heat from the hearth.These must be opened according to the heat requirement.Never overfeed the stove (consult the technical table – max. quantity of fuel that can be fed).Picture 9Picture 10A12CBGPBC2LGDS