CUCINOTTA7093101 - IT - EN - DE - FR 151. TECHNICAL DATADefinition in according to:Constructive systemNominal thermal power in kWEfficiency in %Smoke outlet diameter in mmChimney height ≥ (m) - dimension (mm)Depression by rating calorific value in Pa (mm H2O) - woodHourly wood consumption in Kg/h (wood with 20% humidity)CO measured at 13% oxygen in %Exhaust gas emission in g/s - woodExhaust gas temperature in °C - woodOuter air inlet Ø in mm (minimum surface cm2)Hearth opening size in mm (W x H)Hearth size in mm (W x H x D)Oven size in mm (W x H x D)Type of grill Movable - flatHeight in mmWidth in mmDepth in mmWeight in KgFire prevention safety distances Chapter FIRE SAFETYm3 riscaldabili (30 kcal/h x m3) (#)(#) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume ofthe stoves is:favourable type of building (30 Kcal/h x m3); less favourable type of building (40 Kcal/h x m3); unfavourable type of building(50 Kcal/h x m3).With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating,in the event of interruptions which last more than 8 hours, the heating capacity is reducWed by about 25%.2. GENERAL PRECAUTIONSLa NORDICA S.p.A. responsibility is limited to the supply of the appliance.The installation must be carried out scrupulously according to the instructions provided in this manual and the rules of the profession.Installation must only be carried out by a qualified technician who works on behalf of companies suitable to assume the entire responsibilityof the system as a whole.La NORDICA S.p.A. declines any responsibility for the product that has been modified without written authorisation as well asfor the use of non-original spare parts.It is OBLIGATORY to respect the National and European rules, local regulations concerning building matter and also fireproofrules.NO MODIFICATIONS CAN BE CARRIED OUT TO THE APPLIANCE. La NORDICA S.p.A. cannot be held responsible for lack ofrespect for such precautions.3. INSTALLATION REGULATIONSInstallation of the Product and auxiliary equipment in relation to the heating system must comply with all current Standards and Regulationsand to those envisioned by the law.The installation and the relating to the connections of the system, the commissioning and the check of the correct functioning mustbe carried out in compliance with the regulations in force by authorised professional personnel with the requisites required by the law,being national, regional, provincial or town council present in the country within which the appliance is installed, besides these presentinstructions.Installation must be carried out by authorised personnel who must provide the buyer with a system declaration of conformity and willassume full responsibility for final installation and as a consequence the correct functioning of the installed product.The Product, assembled and ready for the installation, must be connected with a junction to the existing flue of the house. The junctionmust be possibly short, straight, horizontal or positioned a little uphill. The connections must be tight.Before installing the appliance, carry out the following checks:• Make sure that the floor can support the weight of the appliance (for ex. distributing weight plate), and if it is made of flammablematerial, provide suitable insulation (DIMENSIONS ACCORDING TO REGIONAL REGULATIONS). With a flammable floor theappliance must be installed on a 12 cm thick stone or concrete slab.• Make sure that there is adequate ventilation in the room where the appliance is to be installed, with particular attention to windowsCUCINOTTAEN 128151978,11504 - 200x200 Ø20012 ( 1,2 mm H2O)2,70,11 - 1375 mg/m39,5310150 (100 cm2)405 x 325423 x 346 x 475-860682653197258