MODULO ALL INCLUSIVE7095520 - IT-EN-DE-FR 136.5. EXCESS TEMPERATURE ALARMWhen the temperature measured by the water probe exceeds 87°C / 188.6°F (fixed threshold set), this alarm is activated, starting thecirculating pumps.When the alarm is activated, LED 1 Danger comes on and the message “EXCESS TEMPERATURE” is shown on the display.6.6. FAULTY PROBE ALARMWhen a probe fault occurs, this alarm is activated, starting the circulating pumps.When the alarm is activated, LED 1 Danger comes on and the message “FAULTY PROBE” is shown on the display.6.7. AIR VENTAir inside the water circuit causes noise and may damage the circulating pumps. The presence of air may occur following installation of theAll Inclusive Module or any other work on the water circuit.Vent any air inside the system by operating the digital controller as follows:• the water in the system must be at room temperature;• with the digital controller ON, press buttons T2 and T3 together. The display shows the message “AIR VENT”.6.8. SETTINGS MENUSee Chapter 13.Pressing and holding the MENU button (T4) accesses the LANGUAGE menu. (Press T1 to exit the menu).Press the MENU button again briefly to modify the language displayed (IT; EN; DE; FR) using the T2-T3 buttons. Press MENU to confirmthe selection.Press the T2 button to access the BUZZER menu (enable the audible signal). Press the MENU button to enable or disable the buzzer usingthe T2-T3 buttons (ON / Off). Press MENU to confirm the selection.Press the T2 button to access the SET DEGREES menu (display the temperature in °C / °F). Press the MENU button to modify, using theT2-T3 buttons, the temperature display from °C to °F and vice-versa. Press MENU to confirm the selection.Press the T2 button to access the DISPLAY menu (brightness from 0 to 100). Press the MENU button to set the required display brightness,using the T2-T3 buttons, from 0 to 100. Press MENU to confirm the selection.Press the T2 button to access the TECHNICAL SETTINGS menu.WARNING: the parameters in the technical menu should never be modified. Such operation must only be performed by an AuthorisedLa NORDICA S.p.A. Service Centre. La NORDICA S.p.A. is not liable for product malfunctions due to the parameters in thetechnical menu being modified without authorisation.7. “REMOTE” DIGITAL ELECTRONIC REGULATOR MANAGEMENTThis application is useful when the All Inclusive UNIVERSAL module is not installed near the thermoproduct it is associated with.The digital regulator installed in the All Inclusive UNIVERSAL module is managed by the remote regulato (ONLY included in ther standardsupply of the UNIVERSAL module) which has identical functions.When the two digital regulators are connected to each other, the lighting of both screens will be less bright. This phenomenon is completelynormal and has been designed specifically to stop the screens from overheating.IMPORTANT: the ambient temperature is displayed on the remote screen followed by the letter “A”, while the temperature of the water inthe boiler is followed by the letter “R”. The thermoproduct boiler water temperature probe (l1) must be connected directly to the remotedigital regulator. The probe cable can have a maximum length of 5 metres.IMPORTANT: the digital regulator installed in the All Inclusive UNIVERSAL module must be connected to the remote digital regulator, asshown in Picture 2 at page 24, through a bipolar electric cable (NOT included), with a length that does exceed 100 metres8. WATER CIRCUIT MAINTENANCEWith the system switched off, once a year carry out the following checks:• Check the operation and efficiency of the blowdown and safety valves. If they are defective, contact your authorised installer. IT ISSTRICTLY FORBIDDEN TO REMOVE OR TAMPER WITH THE SAFETY DEVICES.• Make sure that the system has been filled and is pressurised (see the manual for the heating appliance combined with the AllInclusive Module).9. SUMMER SET ASIDEATTENTION: the installation must be kept constantly full of water even in periods in which the use of thermofireplaces is not required.During winter time, inactivity must be faced by adding antifreeze substances.OPEN expansion VESSEL system: check the water level in the expansion tank and remove any air from the system by bleeding theradiators; also check to make sure that the plumbing and electrical accessories (control unit, circulator) are working properly..