NORMA IDRO DSA16 7197130 - IT-EN-DE-FR1. TECHNICAL DATADefinition in accordance with EN 13240Constructive systemGlobal thermal power in kWNominal thermal power in kWPower given back to water in kWPower given back to the room in kWHourly wood consumption in kg / h (wood with 20% humidity)Efficiency in %CO measured at 13% oxygen in %Smoke outlet diameter in mmChimney height - dimension in mm (#)Fluid contents of the exchanger (H2O) in L (litres)Chimney draught in Pa (mm H2O)Boiler connections (Ø)Automatic discharge pipe diameter (Ø)Outer air inlet Ø in mm (minimum surface cm2)Exhaust gas emission in g/s – woodExhaust gas temperature in °C - woodOptimal working temperature in °CMax. working pressure in bar (expansion vessel Open - Closed)Hearth opening size in mm (W x H)Hearth size in mm (W x H x D)Oven size in mm (W x H x D)Type of grill Movable - flatHeight in mmWidth in mmDepth in mmWeight in KgFire prevention safety distances Chapter FIRE SAFETYheatable m3 (30 kcal/h x m3) (# #)(#) 200 mm diameter can be used with flue of no less than 6 m.(# #) For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volumeof the product is: favourable type of building (30 Kcal/h x m3); less favourable type of building (40 Kcal/h x m3); unfavourable type ofbuilding (50 Kcal/h x m3).With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating,in the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.IMPORTANT: The power of the connected heating system must be proportional to the power transferred to the water by the thermoproduct;a charge which is too low does not allow regular oven operation, while a charge which is too high prevents adequate radiator heating.2. GENERAL PRECAUTIONSLa NORDICA S.p.A. responsibility is limited to the supply of the appliance.The installation must be carried out scrupulously according to the instructions provided in this manual and the rules of the profession.Installation must only be carried out by a qualified technician who works on behalf of companies suitable to assume the entire responsibilityof the system as a whole.La NORDICA S.p.A. declines any responsibility for the product that has been modified without written authorisation as well asfor the use of non-original spare parts. NO MODIFICATIONS CAN BE CARRIED OUT TO THE APPLIANCE. La NORDICA S.p.A.cannot be held responsible for lack of respect for such precautions.It is OBLIGATORY to respect the National and European rules, local regulations concerning building matter and also fireproofrules.3. INSTALLATION REGULATIONSInstallation of the product and auxiliary equipment in relation to the heating system must comply with all current Standards and Regulationsand to those envisioned by the law.The installation and the relating to the connections of the system, the commissioning and the check of the correct functioning mustbe carried out in compliance with the regulations in force by authorised professional personnel with the requisites required by the law,being national, regional, provincial or town council present in the country within which the appliance is installed, besides these presentinstructions.NORMA IDRO - DSA146,332,418,713,710,7700,181605m – 220x220 Ø2204017 - 20 (1,7 - 2,0)1 ”F gas3/4” M gas200 (100 cm2)31,137870-75VA 1,5 bar - VEC 3 bar424 x 350424 x 450 x 320/1242720575249928