1 2 3Installation 3‐7P/N 397189E 2006 Nordson Corporation BM200_EASY_GEARInstalling Heated HosesWARNING: Hot! Risk of burns. Wear heat‐protective gloves.Laying HosesGuide hose through the hose guide. The hose connection is located on theheating punch.ConnectingIf cold material can be found in the hose connection (1) and/or hose fitting(2), these components must be heated until the material softens (approx.80 C, 176 F).1. First connect the hose (3) electrically to the unit. For more than one hose:Every hose connection is allocated to a corresponding receptacle. Do notmistakenly exchange!2. Heat the system and hose to approx. 80 C (176 F).3. Screw the heated hose onto the unit.NOTE: Close unused hose connections with Nordson port plugs.DisconnectingWARNING: System and material pressurized. Relieve system pressurebefore disconnecting heated hoses. Failure to observe can result in seriousburns.Relieving Pressure1. Set motor speed to 0 min‐1 (rpm); switch off motor(s).2. Place a container under the nozzle(s) of the application head/assemblyhandgun.3. Activate the application head / assembly handgun electrically ormanually. Repeat this procedure until no more material flows out.4. Re‐use the material or dispose of properly according to local regulations.Second Open‐jawed WrenchUse a second open‐jawed wrench when connecting and disconnecting theheated hose. This prevents the unit's hose connection from turning.