Installation 3-3E 2002 Nordson CorporationAll rights reserved ColorMaxIssued 12/02P/N 768625C1. Remove any large items of contamination.2. Switch on booth extraction system.3. Recycle system should be in the spray to waste position.4. With all doors closed, use the low pressure air lance to blow internalbooth faces free of dust.5. Damp sponge with water and wipe clean internal booth faces, basedeflector and internal cyclone access area. A drop of detergent maybe used for the first wash. Repeat the wash with water only.6. While allowing the booth to dry, wipe the exterior of the booth. Theblow lance may be used to decrease the drying time7. With eye protection, mask and gloves:WARNING: Use a sharp solvent (see below) and apply to theinternal parts of the booth, base deflector and internal cycloneaccess area with clean lint free wipers.S Polish dry.S Wipe around one square metre and blow with air lance andproceed until complete.S It is important not to touch the faces wiped with bare hands8. Allow to dry.9. Spray powder to waste for 5 minutes, solvent clean any areas whichpreferentially collect powder.10. Clean cyclone and recycle in the normal way.11. The system is now ready for use12. Normal clean down procedures now apply but it may be necessary tocondition the booth when necessary to ensure the best possiblecolour change.9. Set Up ProcedureBooth Conditioning Procedure