LA 404 Pattern Control System 53Part 1037527B! 2005 Nordson Corporation Manual 66-LA404-MA-01System Settings 2This setup menu is used to configure automatic and manual startup of thepattern controller, the trigger memory function, and to enable and disablethe remote recall of programs.When the autostart feature is on the pattern controller will automatically beplaced in run mode when the unit is powered. When set to off, the patterncontroller will always be placed in STANDBY when the unit is powered.The trigger memory function allows the user to either apply or not applyadhesive to products between the trigger and the guns when line speedrecovers after falling below the stop speed setting. When set to off, thepattern is terminated, and when set to on the pattern resumes when the linespeed is above the start speed setting.The remote recall feature allows the programs to be selected either from thefront panel or remotely from the remote input jack. When set to off, 50programs can be selected from the front panel. When on, 32 programs canbe selected through the remote input jack.+SK:?A!+?::;%8:6K:=5:!!!!!!!!!!!!!-<$5;J!*?A65S!!!!!!!!!!!-MM!!,?A6:?!,?9=FF!!!!!!!!!-MM6640031A1. To set autostart:a. Press the % or & button for the cursor to appear beside On/Off.b. Press the " or # button to select On or Off.NOTE: The Autostart feature controls the enabling and disabling ofpattern generation on power-up. If set to OFF, then all the channels areset to STANDBY on power-up. If set to ON, then all the channels thatwere in RUN when powered down will RUN when powered up. Thedefault setting is Autostart OFF.2. To set trigger memory:a. Press the % or & button for the cursor to appear beside On/Off.b. Press the " or # button to select On or Off.