iTRAX Remote Display 9Part 1076079A 2007 Nordson CorporationData Configuration ProcedureThis example sets the process value data to display:1. Press the Select key to enter configuration mode. Press the Select keyto scroll through the configuration menu items.2. On DATA press the Enter key.3. Use the Up and Down Arrow keys to scroll through the data items.4. Press the Enter key to select a data item. Yes appears if the item wasselected for display previously, No if it was not.5. Use the Up or Down Arrow keys to toggle between Yes to display or Noto not display.6. Press the Enter key to select Yes or No. SAVE appears, thendisappears and the data item name appears.7. Use the Up or Down Arrow keys to scroll through the rest of the DATAmenu items.8. Press the Select key to exit the DATA menu.Configuration - PRx Module DataMake the following required and optional settings to configure the RemoteDisplay to display PRx module data. See Figure 6 for the menu map.Menu Function and DefaultMODE Mode to enter: DISP (Display mode) or CONF (Configuration mode). Pressing the Selectkey while in Display mode automatically sets the mode to CONF. Select DISP to return todisplay mode from configuration mode. On power up the factory default is DISP.INTR Display Interval (1-60 seconds): Time to display each process data value. If more thanone process data is selected, each data value is display for this time, in sequence.Default is 5 seconds.COMM Set communications protocol: CAN1, CAN2, 485 (RS485). Set to 485 for PRx modules.The factory default is RS485.DATA Process data to display: BASE (base pressure), TEMP (fluid temperature), RPM (beltspeed). The factory default is BASE only. If more than one is chosen for display, theneach is displayed in sequence.NOTE: To configure the process data, refer to the Data Configuration procedure above.UNIT Display units: ENGL (English) or METR (Metric). The factory default is English.ADDR 1-4. The factory default is 2. The PRx module is always set to 1.