3GQuick ConnectCordRemote Controller Cord Gas Supply PipingCold Water SupplyHot WaterRemote ControllerTerminal BlockCordConnectorCordConnector3. Quick Connect Multi System Installation• The Quick Connect Multi System allows the installation of two units together utilizing only the QuickConnect Cord.Typical Plumbing* When connecting two units, use only asingle remote controller.Note: Connect the remotecontroller to only oneof the units.System Diagram• Insulate the hot water piping to prevent heat loss. Insulate and apply heating materials to thecold water supply piping to prevent heat loss and freezing of pipes when exposed to excessivelycold temperatures.UnionMake this distance as short as possible.* The hot water temperature willbecome unstable as the pipelength increases.Quick ConnectcordUnionGas ValveUnionShutoffValve Shutoff ValveHot WaterCold WaterLeave enough clearance around the plumbing toapply insulation. It will be necessary to addbends to the piping to ensure that this clearanceis available.PressureReliefValveShutoff ValveSize the piping to allow for themaximum flow rates of the units.The backflow preventer isput up before it diverges.Distance at center: 20.3 - 36.3 in. (515 - 922mm)Distance on sides2 - 18 in. (50 - 457mm)The Quick Connect Cord is 6 ft.(2m) long. Install the units 2-18" (50 - 457mm) apart from eachother to ensure the cord will be able to reach between the units. (See Typical Plumbing diagram).(If the distance between the two units is too great, not only will the cord not be able to reach,but the water temperature may also become unstable because of the difference in pipe lengthbetween the two units).