15Nortel WLAN - Security Switch 2300 Series Quick Start GuideQuick Start — Physical InstallationThis section describes how to physically install a WSS. For more information about physical installation, see NortelWLAN—Security Switch 2300 Series Installation and Basic Configuration Guide.Installing the Nortel WLAN Security SwitchEstimated timing: 10 minutesA WSS can be installed on either a tabletop surface or in an equipment rack. Table 2 outlines which installationmethods are available for each WSS model.When choosing a location for the WSS, ensure that:• The power outlet is within 1.82 m (6 ft) of the device.• There is proper heat dissipation from and adequate ventilation around theswitch.Tabletop InstallationStep Action1 Ensure that the table surface supports at least 3 kg (6.6 lb).2 Carefully turn the WSS upside down on a clean work surface with no debris.3 Wipe the four placement locations for the rubber feet to clear away any oil or dust.Each location area is marked with an ‘X’.4 Attach the four rubber adhesive feet over the ‘X’s.5 Turn the WSS right-side up, and place the switch in position on the table.EndEquipment Rack InstallationStep Action1 Remove the four bracket screws from each side of the WSS.2 Align a bracket over the screw holes:• For a front-mount equipment rack, align the bracket so that the bracket flange isflush with the WSS front panel and away from the switch.• For a center-mount equipment rack, align the bracket so that the bracket flangeis located near the center screw holes, as shown in Figure 2.Table 2: Installation methodsWSS model Tabletop Front-mount rack Center-mount rack2350 X2360/2361 X X2380 X X X2382 X X X