Replacing equipment Page 201 of 250Hardware ReplacementConnect the Network shelf 0 3PE cards to Core/Net 01 Connect a NT8D76 cable of the appropriate length from J3 on the 3PEcard faceplate in Network group 1, shelf 0 to the Port 9-1, J3connection on the 3PE Termination Panel in Core/Net 0.2 Connect a NT8D76 cable of the appropriate length from J4 on the 3PEcard faceplate in Network group 1, shelf 0 to the Port 9-1, J4connection on the 3PE Termination Panel in Core/Net 0.3 Connect a NT8D76 cable of the appropriate length from J3 on the 3PEcard faceplate in Network group 2, shelf 0 to the Port 10-0, J3connection on the 3PE Termination Panel in Core/Net 0.4 Connect a NT8D76 cable of the appropriate length from J4 on the 3PEcard faceplate in Network group 2, shelf 0 to the Port 10-0, J4connection on the 3PE Termination Panel in Core/Net 0.5 Install the remaining cables according to the assignments in Table 3on page 199.Connect the Network shelf 1 3PE cards to Core/Net 11 Connect a NT8D76 cable of the appropriate length from J3 on the 3PEcard faceplate in Network group 1, shelf 1 to the Port 9-1, J3connection on the 3PE Termination Panel in Core/Net 1.2 Connect a NT8D76 cable of the appropriate length from J4 on the 3PEcard faceplate in Network group 1, shelf 1 to the Port 9-1, J4connection on the 3PE Termination Panel in Core/Net 1.3 Connect a NT8D76 cable of the appropriate length from J3 on the 3PEcard faceplate in Network group 2, shelf 1 to the Port 10-0, J3connection on the 3PE Termination Panel in Core/Net 1.4 Connect a NT8D76 cable of the appropriate length from J4 on the 3PEcard faceplate in Network group 2, shelf 1 to the Port 10-0, J4connection on the 3PE Termination Panel in Core/Net 1.5 Install the remaining cables according to the assignments in Table 3on page 199.NT8D3703 IPE Module Card CageTo replace a defective backplane in an NT8D37 IPE Module, you mustreplace the card cage. Use this procedure to replace the IPE Module cardcage.