WHEN AUDIBLE DEVICES ARE SOUNDING -FOR AN ALARM1. Evacuate the protected area2. Notify the monitoring service and/or the Fire Department immediately. Tell them briefly what happened and whatyour current status is.Phones: ____________________________ _________________________________Fire Department Monitoring Service3. If the Fire Department is responding, be prepared to provide directions to arriving firefighters.FOR TROUBLE ONLY1. Notify the monitoring service and/or Fire department if this panel is connected to either one, and tell themwhat is happening.2. Silence audible devices by unlocking and opening the panel and pressing the ACKNOWLEDGE/STEP key. Theyellow system TROUBLE LED will remain on. Contact authorized service personnel immediately! (See Below).WARNING!DO NOT ALLOW TROUBLE CONDITIONS TO REMAIN LOGGED IN THE SYSTEM. THE PROTECTIONTHE SYSTEM OFFERS HAS BEEN COMPROMISED, OR ELIMINATED WHEN A TROUBLE CONDITIONEXISTS.To return to normal after an alarm1. Do not enter the protected area until safe to do so.2. Clear all initiating devices. Smoke detectors will not resetif there is still smoke in the area.3. Reset the control panel (PRESS the RESET key)Power failure or brownoutIf AC power drops too low or fails, the AC POWER LED will go out,the system TROUBLE LED will turn on, and the panel buzzer andany other audible trouble devices will sound. Contact authorizedservice personnel immediately. See below.Manual activation (Fire Drill or otherwise)Notification Appliance Circuits (NACs) can be activated bypressing and holding the DRILL key for at least two seconds.NOTE: You may want to disconnect municipal box by slidingDISCONNECT switch, located on 4XTM module, to itsdisconnect position (to the right). If a DACT isconnected, notify the monitoring service beforeconducting any fire drills or tests.FireWarden-100-2/E Fire Alarm Control PanelOperating InstructionsPANEL KEY - The key to open the panel can be found at thefollowing location:NORMAL - Only the GREEN A.C. POWER LED is on.All other LED's are off. LCD display will read SYSTEM ALLNORMAL.Document #52781 Rev. A 11/15/05 ECN 06-086THIS SHEET SHALL BE FRAMED ADJACENT TOTHE CONTROL PANELTo test the lamps, LCD display and piezo sounderPress and release the RESET key and check all LED's. Every LEDshould be on, LCD shows all pixels on, piezo sounder beeps.For more information, refer to the FireWarden-100-2/E Manual,Document #52778. It is kept in the following location:Alarm SilencingNotification Appliance Circuits may be silenced by pressing theALARM SILENCE key. The ALARM SILENCED LED will turn on.Subsequent alarms will reactivate circuits. Press the RESET keyto clear the "silenced" condition.NOTE: Notification Appliance Circuits may be programmed asnonsilenceable. Also, Signal Silence Inhibit, if enabled, willprevent silencing of NACs for one minute after an alarm (seemanual).Name: _____________________________________Company: _________________________________Address: ___________________________________Telephone Number: ________________________In the event of trouble, contact thelocal Notifier Service RepresentativeService Representative