Subject to change Page 13 of 26 Version 2.2 / Date: Sept 2013NovaTec Kommunikationstechnik GmbH E-Mail: info@novatec.de Phone: +49 (0)5251 1589-610Technologiepark 9 / DE-33100 Paderborn Internet: www.novatec.de Telefax: +49 (0)5251 1589-6116 Delivery StatusThe S3 is delivered as follows:- a factory set-up (see 6.1) is installed,- a factory firmware is installed- a factory license (see 6.2) is installed (from FW-Version 00.07.00.63; NMP 6.5),- the customer specific configuration is installed (if ordered).The current firmware version can be downloaded from www.novatec.de > Downloads.The firmware license for the current firmware is delivered by email as soon as the S3 is dispatched.6.1 Factory Set-UpDHCP with option 129 is activated in the factory set-up.The system will try for approx. one minute to reach the DHCP server after being restarted. If the DHCPrequest runs fail the system will fall back into the following IP default adjustment- IP-address:192.168.127.254- Subnet mask: 255.255.0.0- Default-Gateway:192.168.1.254.Please consider the following with modifications of the factory set-up:If no DHCP server is available under „System IP Option“ in the configuration the existing entry „DHCP on“has to be changed to „DHCP off“.6.2 Firmware-LicenseFrom firmware version 00.06.07.00 you need a firmware license to ensure the functionality of the S3. Ifthis license is missing telephony is not possible and only remote access is possible.The license is already on board if the S3a. was delivered with firmware 00.07.00.63 or higher orb. was delivered with a firmware < 00.07.00.63 but configured by NovaTec .The license data has to be uploaded onto the system with the NovaTec configuration interface ifa. the S3 was delivered with a firmware < 00.07.00.63 and hasn’t been configured by NovaTec orb. an upgrade onto firmware 00.07.00.63 or higher is effected orc. the current firmware is to be installed (see 6)The following points have to be considered when updating S3-systems:a. Systems with a firmware version older/smaller than 00.06.07.00:An update onto firmware 00.06.07.00 or higher always requires a license key. The license cannotbe readout of the system or stored.b. Systems configured with NMP 6.3.2 or 6.4:To copy the configuration onto the target system a license key is required irrespective of the firm-ware version. The license key has to be uploaded uniquely with the NovaTec configuration inter-face into the data base before the configuration can be transferred. The license cannot be readout