- 59 -8. SYSTEMSystem Setup allows modification of various system features such as general, time, user accounts,disk, update, and information.8.1 GENERAL8.1.1 SYSTEM IDSelect the DVR’s SYSTEM ID. Up to 99 DVRs can be controlled using one remote controller. Toselect the DVR to be controlled with the remote controller, press and hold the DVR ID button. Whileholding the DVR ID button, press the appropriate DVR ID number, and then release the DVR IDbutton.For example, enter 05 for DVR ID 05; enter 43 for DVR ID 43, and such. The default value is 00.8.1.2 AUTO LOCKThe DVR locks all the buttons after three minutes of inactivity. The buttons can be unlocked with theuser password. The default is OFF.8.1.3 RECORD MODESelect the global record resolution. Values are 360 x 240 (CIF), 720 x 240 (Field) and 720 x 480(Frame). The default is 360 x 240 (CIF).Note: Maximum global record rate is 120 pictures per second at the resolution of 320 x 240(CIF), 60 pictures per second at the resolution of 720 x 240 (Field), and 30 pictures per secondat the resolution of 720 x 480 (Frame).The option “FRAME + CIF” is recorded at Frame resolution for ch1, and CIF resolution forothers.8.1.4 PB DEINTERLACEDe-interlace picture to eliminate white interlace lines during Playback.8.1.5 RUN ON BOOTThe DVR start the recording itself when the DVR is booting up.8.1.6 PASSWORDTo disable the password prompt window when entering menu.8.1.7 FACTORY DEFAULTTo restore factory default settings, stop recording and select the START option.