Alaris Site Preparation GuideObjet Confidential and Proprietary InformationDOC-04002 16 Rev. C5.5 NetworkA network connection is required near the server workstation.Figure 5–1 Network connection5.6 Heat DissipationTable 7 describes the heat dissipation of the system units.5.7 Air ConditioningRoom air conditioning must be designed so that the temperature andhumidity specifications described below are maintained when the systemoperates at full power.5.7.1 TemperatureThe temperature in the room containing the Alaris system should be 18 °Cto 25 °C (64.5 °F to 77 °F).Alaris printerAlariscomputerCrossed Network Cable5 m (16' 5")Point-to-Point To local networkServerWorkstationThe Alaris printing system enables printing from all workstations connected to thecustomer’s network. Therefore, during the site preparation, identify all suchworkstations to ensure that each has the correct operating system and computerspecifications.Unit Estimated Heat DissipationAlaris printer 760 W (2600 BTU)Server workstation 450 W (1530 BTU)Table 7: Heat dissipation per unit