354. Repeat step 3 when necessary.5. Press [4] to end the test (the state for step 1 is restored).Density adjustment test itemsDisplay DetailDENS ADJ EXECUTE Executes density adjustment.DENS ADJ PAR-SET Sets a control value for auto density adjustment.DENS ADJ RESULT Displays the result of density adjustment.AUTO CALIBRATION Automatically sets a density sensor sensitivity correction value.AUTO CALIB BLACK Automatically sets a black density sensor sensitivity correction value.2.8.6 Consumable Counter DisplayThe consumable counter display is used for viewing the usage of consumables.1. Enter the normal self-diagnostic mode and, until CONSUMABLE STATUSappears, press [2] or [8] ([2] displays the next test option and [8] displays thepreceding test option). Then press the [6] button.2. Press [2] or [8], and the usage of each consumable appears (the [*] or [#] button isdisabled).3. Press [4] to end the option (the state for step 1 is restored).Upper Display Lower Display Format Unit DetailK-ID UNIT ********IMAGES Decimal ImagesY-ID UNIT ********IMAGES Decimal ImagesM-ID UNIT ********IMAGES Decimal ImagesC-ID UNIT ********IMAGES Decimal ImagesEach display the number of turnsperformed to date after theinstallation of a new image drumunit, converted on an A4 andthree-pages-per job basis.FUSER UNIT ********PRINTS Decimal Prints Displays the number of pagesprinted to date after theinstallation of a new fuser unit.TR BELT UNIT ********IMAGES Decimal Images Displays the number of pagesprinted to date after theinstallation of a new belt unit.K-TONER(FULL)********% Decimal %Y-TONER(FULL)********% Decimal %M-TONER(FULL)********% Decimal %C-TONER(FULL)********% Decimal %Each displays the usage of tonerof a color.K-STC MODECNT********TIMES Decimal TimesY-STC MODECNT********TIMES Decimal TimesM-STC MODECNT********TIMES Decimal TimesC-STC MODECNT********TIMES Decimal TimesEach displays the print dot countof toner of a color (life countervalue after the printer goes intooperation).