Page: 36Service Manual - OKIPAGE10iChapter 3 Parts Replacement(1) Remove the upper cover assy (see 3.3.1).(2) Remove the operator panel assy (see 3.3.4).(3) Remove the face up stacker assy (see 3.3.8).(4) Remove the reset lever R (1).(5) Detach the reset spring (2) from the lower base unit (3), turn the reset lever L (4) in the direction ofarrow A until it stops, and remove it in the direction of arrow B .(6) Unlock two latches of the lower base unit (3), then remove the stacker cover assy (5).Note: When reinstalling the reset lever L (4), fit it onto the guide of the lower base unit (3), turn it in thedirection of arrow C while pressing down the shaft of back up roller, and engage the reset lever L (4).Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA BusinessPartner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)