24 921468007_09_010OFF on an armed system and ON on a disarmed system and ALWAYS ON. This option is not validon wireless keyboard BS-477.«BUTTON PANIC» We select if a panic signal alarm can be issued from the keyboard. If we selectYES, then, when a user presses simultaneously the keys C and ABC for two seconds, a panel alarmwill be produced. This option is valid on wireless keyboard BS-477 too, but by pressing "# ESC"button for 5 seconds. This key works even if the system is armed.«RECORD OUTPUTS EVENT». We select whether the state of the outputs will be logged as individu-al events (Ρ1, Ρ2, Ρ3 and RELAY) or not.«AUTOMATIC BYPASS». By selecting YES, all zones that have been programmed with bypass ca-pabilities (see zone programming), are bypassed automatically, if during the arming sequence theyare active (i.e. an open window). When the zones are deactivated (i.e. the window has closed) theyare automatically activated. If we select NO, then, if there are active zones during the arming proce-dure, the system will request a bypass confirmation for each active zone.«REMOTECONTROL ACTION». We select the operation mode of the remote control (if available).The available actions are "ARM-DISARM", "PANIC", "ALL FUNCTIONS" and "DEACTIVATION".When ‘’ALL FUNCTIONS‘’ is selected, we can perform arming, disarming, panic alarm and silentalarm. For wireless operation use the YET-205B-630 remote control receiver and RF-467 remote con-trol transmitter.«ANNUAL CHECK WARNING». By selecting YES, the system will issue a reminder signal after 1 yearof operation, in order to notify the user for the annual technical inspection.Automatic arming-disarming«TECHNICIAN MENU» «TIMERS» :With this selection we can program up to 10 automatic arming or disarming procedures of all or part ofthe system. Selecting «TIMERS» an the next screen appears:The user has to enter a timer number. The following screen ap-pears.If the «CHANGE TIMER» is selected it means that the timer isactive. If the «DELETE TIMER» is highlighted then this meansthat the timer is inactive. The inactive timer always has a de-fault time of 12:00The selection «CHANGE TIMER» is also used to create a pro-cedure.CHANGE TIMERSELECT FROM 01-10- -______ TIMERS________CHANGE TIMERDELETE TIMER