6InstallationTechnical SpecificationsInstallation must be executed by qualified personnel in compliance with local regulations.EQUIPMENT HOOK-UPThe oven is not provided with power supply cable. When connecting the appliance electrically, an automaticRCD must be interposed with an opening distance between contacts of at least 3 mm. To connect theappliance electrically it is essential to proceed in the following way:• Raise the cover of the terminal block.• Connect to the terminal block the power cable.The power supply cable must be of H07-RNF type, with approved minimum cross section as prescribed by thespecific directive.The electrical outlet must be easy to access, no moving should be necessary.It is mandatory that the electrical system is equipped with a ground connection.The appliance must be part of an equipotential system. The connection is done on terminalmarked with symbol which you will find near the cable clamp. The section of the equipotentialwire must be at least 10 mm2.The equipotential symbol is showed in the following figure.Net Weight(Full Refractory Stone) 96 kg. / 211 lbs. 193 kg. / 425 lbs.Gross Weight 88 kg. / 194 lbs. 165 kg. / 363 lbs.Gross Weight(Full Refractory Stone) 110 kg. / 242 lbs. 209 kg. / 460 lbs.