84 For Long and Trouble-Free Operation: Warning and Error Messages• The OSD displays messages when warnings or errors occur.Detailed Warning and Error InformationDisplay of information on operational warningsMonitor display Description Deck operationCANNOT RECDisplayed when data cannot be recorded on a P2 card.[Meaning]• The card is write protected.• No more free space on the card.• You are trying to record on a card that cannot be used.• Card status changed during recording.• VFR recording started but no active frame data was input.• Recording was attempted when the unit was BUSY.STOPCANNOT LOOP RECDisplayed when ON is selected in menu SETUP - BASIC - LOOP REC and the P2 cards arenot available for recording.[Meaning]• The card is write protected.• No more free space on the card.• You are trying to record on a card that cannot be used.• Card status changed during recording.• Recording was attempted when the unit was BUSY.STOPCANNOT PLAYDisplayed when playback was interrupted due to a clip error or other factor.[Meaning]• Playback was attempted on card without any clips.• Playback was attempted on a card not available for playback.• Other causes that prevent playback or stops playback.• Playback was attempted when the unit was BUSY.STOPTEXT MEMO INVALID Displayed when a text memo cannot be recorded (for example, 100 or more text memoshave been recorded).OperationcontinuesINT SGDisplayed for the first 2 seconds when INT SG is selected in menu SETUP - VIDEO - INPUTSEL or in menu SETUP - AUDIO - INPUT SEL and the REC button is pressed to engageEE mode.OperationcontinuesNO INPUT Displayed for the first two seconds when the REC button is pressed to enter EE modeand INPUT SEL is set to a connector with no input except for analog audio signals.OperationcontinuesTEXT MEMO Displayed for two seconds when a text memo is added. OperationcontinuesMARK ON / MARK OFF Displayed for two seconds when a shot mark is added or deleted. OperationcontinuesSLOT SEL INVALID Displayed when the SLOT SEL button (when assigned to a USER button) was pressed whenit is not possible to switch P2 card recording slot.OperationcontinuesBUSYDisplayed while clip information is being read or when clip configuration has changed. Nooperations can be performed while BUSY is on the screen.[Meaning]• A card has been inserted or removed.• Updating is in progress• Recording post processing is in progress• Other causesOperationcontinuesREF ERRORDisplayed when the REF IN connector signal differs from the system frequency or is notsynchronized with SDI input signals, or in other situations when synchronization with thereference signal is not possible. The unit will not operate normally when this warning isdisplayed. Check connections and input signals.Operationcontinues