■ RS485 Communication line wiring■ Terminal arrangement■ Applicable cables32ON16 8 4 2 11 2 3 4 5 6ON1 2 3 4 5 6ON1 2 64 53This product detects the presence of humans by measuring the temperaturedistribution in the detection area and detecting the movement of objects thathave a higher temperature than the background.* A human body may not be detected when the difference between its surfacetemperature and the room temperature is small.Near the air outlet of an airconditioner, etc.A place with highly reflectivefloor surfacesA place with rapid temperaturechangesA place with an automated movingobjectA place where the floor temperatureis high due to sunlight, floor heating, etc.A place with swinging objectsDetection range (estimate) when the ceiling is 2.7 m high3.6 m1.6 m100 mm+50EDC24V(DC24V)DC24VOND ONDE EDC24V DC24VOND ONDEDC24V GND E EDC24V GNDRS485 RS485 TerminationModel No.Installation InstructionsPlease make sure to read this manual before installation.Safety Precautions Please make sure to followWarningMust be followed● Insert cables deep enough for ensuring a wire connection.Inadequate insertion may produce heat, causing burnout or fire.Avoid installation in the following places.Wiring DiagramPowersupplyPowersupply PowersupplyControldeviceInput Feed Termination(Input) (Feed)(Input) (Feed)Termination sideD class grounding D class groundingContact outputThe termination-side device'sfeed and termination terminalsmust be connected to each other.• Use shielded twisted pair cables.• The shield must be grounded at one end. Ground terminals are for grounding onlyand require D class grounding.• Use transition wiring for device connections. (Branch wiring not applicable)Power cable0.65 to 0.9 Cu (copper) Single wire onlyRS485 signal cable0.65 to 0.9 CPEV cableAdvance Check Items and Installation Requirements1. Avoid incorrect wire connections and short circuits.2. Wipe off stains using soft, dry cloth without scratching.Avoid using thinners, alkaline detergents, acid detergents, cleansers,pesticides, etc. Their use may cause a failure.Detection RangeHow to MountRS485 Address SettingOperation lampIlluminates red when a humanbody is detectedNote: The detection rangevaries depending on theinstallation height.● The ceiling height must be 2.7 m or lower.The product cannot be used on a sloped ceiling.Depth above the ceilingsurface: 50 mm or moreClaw partRemovalgroove* Check the detectionrange after installation.Area mask settingswitch (4-bit)Reset switchPress the reset switchafter setting changes.SensorCeiling board thickness:30 mm or lessLower the fitting to fix byturning the screw witha Philips screwdriver.* Remove the protectionfilm attached to the sensorsurface before mountingthe cover.Note: Do not touch thesensor surface.CoverClamping metal fittingHow to Remove the CoverScrewdriverBinary numbers Example of address settingRemoval grooveTurn right and left CoverCeiling surfaceAddress setting switch(6-bit)Address: 1Address: 8* Use binary numbers for address setting.