Operating Instructionsz AW-RP50z AW-RP120z AK-HRP200• It may be necessary to upgrade the version of the controller in order to support the unit.For details on upgrading, visit the support page on the following website.http://pro-av.panasonic.net/• The following operations can not be performed via the following controllers.Item AW-RP555 AW-RP655Camera OSD menu operation Supported SupportedScene Supported *1(1/2/3/USER)Supported(HALOGEN/FLUORESCENT/OUTDOOR/USER)Iris Mode Supported SupportedShutter Mode Supported with some restrictions *2(Step only) Not supportedGain Supported *1 Supported with some restrictions *3ND Filter Not supported Not supportedDay/Night Supported with some restrictions *4 Supported with some restrictions *4White Balance Mode Supported *1(AWB A/AWB B/ATW only)Supported(AWB A/AWB B/ATW only)AWB/ABB Supported SupportedColor Temperature Not supported Not supportedR Gain / B Gain Not supported SupportedPedestal Not supported SupportedR Pedestal / B Pedestal Not supported Supported with some restrictions *5Detail Not supported Not supportedV Detail Level Not supported Not supportedCAM/BAR Supported *1 SupportedPan Supported SupportedTilt Supported SupportedPreset Supported SupportedPreset Speed Not supported Not supportedPreset Speed Table Not supported Not supportedPreset Scope Not supported Not supportedFreeze During Preset Not supported Not supportedFocus Mode Supported with some restrictions *4 Supported with some restrictions *4Zoom Supported SupportedDigital Extender Not supported Not supportedOIS/D.I.S.S. Not supported Not supportedTally Supported with some restrictions *6 Supported with some restrictions *6*1 If the setting value is changed on another device, it may take some time for the setting value to be applied.*2 If the Shutter Mode is not turned off/on after configuration, the value will not be changed.*3 Improper operation will occur when Gain is set to 19 dB or higher.*4 If the setting value is changed on another device, the setting value will not be applied. (If the value is configured locally on the device, the value willbe applied.)*5 The value range display will be incorrect (–150 to +150).*6 Although the unit is not equipped with a tally lamp, the “OSD Off With Tally” function can be used. Functions that cannot be controlled with the standard protocolOperations for the following items cannot be controlled with the standard protocol.Item Standard protocol incompatibilityHeater Control not possibleWiper Control not possibleDefroster Control not possibleWasher Control not possibleOIS/D.I.S.S. Setting not possibleAudio Setting not possibleDC Out Control not possibleTally Display function not available on unitController supported31