8.1.14. Auto Restart Control1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to fourminutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after powersupply resumes.2. This type of control is not applicable during ON/OFF Timer setting.8.1.15. Indication PanelLED POWER MONITOR POWER QUIET TIMER POWERFUL IONColor Green Green Orange Orange Orange GreenLight ON Compressor ON Operation ON Quiet Mode ON Timer Setting ON Powerful Mode ON Ion Mode ONLight OFF Compressor OFF Operation OFF Quiet Mode OFF Timer Setting OFF Powerful Mode OFF Ion Mode OFFNote:• If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation modejudgment, or delay ON timer sampling.• If Timer LED is blinking, there is an abnormality operation occurs.• If Ionizer, LED is blinking, there is an abnormality of Ionizer occurs.Power Monitor LED Control FrequencyLighting of 3 LED base on instructed running frequency from indoor unit to compressor at cool, dry & heating operation.Position of LEDCool, DryInstructed Hz No0 Hz 35 35 Hz 59 Hz 59HeatInstructed Hz No0 Hz 44 40 Hz 63 Hz 638.1.16. Auto Operation Switch1. When the switch is pressed between 0 to 5 seconds, Auto Mode operation starts to function.2. When the switch is pressed between 5 to 8 seconds, the unit is forced to operate in Cooling Mode.3. When the switch is pressed between 8 to 11 seconds, the unit is forced to operate in Heating Mode.4. When the switch is pressed between 11 to 16 seconds and together with the signal from remote control, the unit can bechanged to different controlling setting (4 type of transmission codes).5. When the switch is pressed between 16 to 21 seconds, either “H14” error detection selection mode or the remote control signalreceiving sound can be cancelled or turned on.29