33A. Basic Rotation Speed (rpm)i. Manual Fan Speed[Cooling, Dry]• Fan motor’s number of rotation is determined according to remote control setting.[Heating]• Fan motor’s number of rotation is determined according to remote control setting.ii. Auto Fan Speed[Cooling, Dry]• According to room temperature and setting temperature, indoor fan speed is determined automatically.• The indoor fan will operate according to pattern below.Remote Control O O O O OTab Hi Me+ Me Me- LoRemote Control O O O O OTab Shi Me+ Me Me- Lo12.1.5. Automatic Operation• This mode can be set using remote control and the operation is decided by remote control setting temperature, remote controloperation mode and indoor intake air temperature.• During operation mode judgment, indoor fan motor (with speed of Lo-) is running for 30 seconds to detect the indoorintake air temperature.• Every 10 minutes, the indoor temperature is judged.• For the 1st judgment- If indoor intake temperature - remote control setting temperature ≥ 2°C, COOL mode is decided.- If -2°C ≤ indoor intake temperature - remote control setting temperature < 2°C, DRY mode is decided.- If indoor intake temperature - remote control setting temperature < -2°C, HEAT mode is decided.• For the 2nd judgment onwards- If indoor intake temperature - remote control setting temperature ≥ 3°C, if previous operate in DRY mode, then continue in DRYmode, otherwise COOL mode is decided.- If -2°C ≤ indoor intake temperature - remote control setting temperature < 3°C, maintain with previous mode.- If indoor intake temperature - remote control setting temperature < -2°C, HEAT mode is decided.12.2. Indoor Fan Motor Operation-6 -5 -4 -3 -2 -1 210 43 65Heat Dry Cool-6 -5 -4 -3 -2 -1 210 43 65HeatMaintaincurrent modeCool/Dry