– 18 –CS-G93KE2. COOLING OPERATIONA. Room Temperature Control(i) When the remote control setting temperature is less than 24°C.Operation DetailsCoolingIntake air temp. –Internal settingtemp. (°C)Internal setting temp.Compressor OFF temp.Outdoor Air TemperatureModel No.+1.5+1.0+0.50–0.5–1.064 (Fc max) or 503631151515Comp OFFLess than 38°CCompressor Operation Frequency (Hz)92 (Fc max) or 704431161515Comp OFFLess than 38°C64 (Fc max) or 504031221515Comp OFF38°C and above92 (Fc max) or 704931221615Comp OFF38°C and aboveCS-G93KE CS-G123KE(ii) When the remote control setting temperature is 24°C and above.CoolingIntake air temp. –Internal settingtemp. (°C)Internal setting temp.Compressor OFF temp.Outdoor Air TemperatureModel No.+1.5+1.0+0.50–0.5–1.064 (Fc max) or 503631151515Comp OFFLess than 38°CCompressor Operation Frequency (Hz)92 (Fc max) or 704431161515Comp OFFLess than 38°C64 (Fc max) or 503631151515Comp OFF38°C and above92 (Fc max) or 704431161515Comp OFF38°C and aboveCS-G93KE• Compressor OFF temperature = Compressor ON temperature.• The operation frequency can be changed every 30 seconds.• 30 minutes from the start of the operation, the compressor is operating at Fc max Hz.• The compressor stops when the intake air temperature reaches 1°C below internal setting temperature andcontinues for 3 minutes.• When the compressor stops, it will not begin operation for 3 minutes. (Time Delay Safety Control)• When the intake air temperature reaches the Compressor ON temperature, the Compressor starts operation.• When the compressor stops, the outdoor fan motor stops 30 seconds later.CS-G123KE