– 38 –CS-G93KEOperation Details(b) Manual Horizontal vane angle setting• By pressing the remote control horizontal airflow direction setting switch, the vane will move to the indicatedposition (1, 2, 3, 4, 5, 6, 7) as shown in the table.The purpose of this control is to reduce indoor operating noise. Indoor fan speed is set to Lo- when the followingconditions occur.• Indoor fan speed is set at Low• Indoor heat exchanger temperature rises to 17°C or above• Compressor operates for 5 minutes or more• Operation frequency is less than 33Hz (CU-G93KE) or 36Hz (CU-G123KE)This control is cancelled when one of the following conditions occurs.• Indoor fan speed is not set at Low• Indoor heat exchanger temperature is decreased to 13° C or below• Compressor operation frequency is more than 33Hz (CU-G93KE) or 36Hz (CU-G123KE)Lo-LoIndoor HeatExchanger Temperature13°C17°C• Horizontal vane angle position10. QUIET OPERATION1 2 3 4 5 6 7OperationHeating(Left vane position) (Right vane position)2125°125°110°125°110°125°355°55°64°55°64°55°455°55°64°55°64°55°555°55°64°55°64°55°690°90°90°90°90°90°7125°125°110°125°110°125°190°90°90°90°90°90°2125°125°110°125°110°125°355°55°64°55°64°55°4125°125°110°125°110°125°590°90°90°90°90°90°655°55°64°55°64°55°755°55°64°55°64°55°190°90°90°90°90°90°Anti-dew Formation ControlAnti-dew Formation ControlFanSoftDryCool-ing(c) Wide / Spot Airflow SettingBy pressing the remote control WIDE/SPOT switch, the vane will move to position 3 while WIDE and position2 while SPOT.WIDE SPOT3 2For AllOperations