•••• [Thermostat-ON Temperature] = [Intake Air Temperature] -[Remote Controller Setting Temperature] < -1.5°C•••• [Thermostat-ON Temperature] = [Intake Air Temperatureafter 2 minutes] - [Remote Controller Setting Temperature]< -1.5°C•••• When Room Temperature is below Thermostat-OFFTemperature for 3 minutes or more, it turns to Thermostat-OFF.•••• The maximum power is applied only for the first 30 minutesof the operation, after that, rated power is applied. If thePOWERFUL Switch is pressed during operation, themaximum power will be applied for 30 minutes.•••• [Thermostat-OFF Temperature] = [Intake Air Temperature]- [Remote Controller Setting Temperature] > +2.0°C•••• [Thermostat-ON Temperature] = [Intake Air Temperatureafter 2 minutes] - [Remote Controller Setting Temperature]< +2.0°C.•••• When Room Temperature exceeds Thermostat-OFFTemperature for 3 minutes or more, it turns to Thermostat-OFF.•••• When operation in rated power continues for 3 minutes ormore, it turns to the maximum power.Cooling power CS-HE9DKE CS-HE12DKEMaximum power 3.0kW 4.0kWRated power 2.6kW 3.5kWMinimum power 0.6kW 0.6kWCooling power CS-HE9DKE CS-HE12DKEMaximum power 6.5kW 7.7kWRated power 3.6kW 4.8kWMinimum power 0.6kW 0.6kW9.3. Room Temperature Control (Compressor Control)Operating frequency of a compressor is decided according to temperature differences between remote controller setting androom temperatures. By adding a relative method, based on current frequency, which gives frequency changes, a roomtemperature is adjusted.9.3.1. Cooling Operation9.3.1.1. Thermostat Control9.3.2. Dry Operation9.3.2.1. Thermostat Control•••• The unit can be operated in the Scrolling Dry Operation by selecting Cooling DRY mode with the DRY button on the remotecontroller.•••• [Thermostat-OFF Temperature] = [Intake Air Temperature] - [Remote Controller Setting Temperature] > -2.0°C•••• When Room Temperature exceeds Thermostat-OFF Temperature for 3 minutes or more, it turns to Thermostat-OFF.•••• The fan speed setting is selectable. → Five stages manually and one stage automatically (QUIET). (Same as Cooling mode.)9.3.3. Heating Operation9.3.3.1. Thermostat Control22CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE