9.6.2. Cooling Operation1. Automatic Fan SpeedOdour Cut Control makes fan stop temporarily for 40 seconds at the beginning of unit operation or Thermostat-ON in order towash away odour ingredients from heat exchanger with dehumidifying water. Fan operation is repeated every 20 seconds at aspeed of "SLo" (Refer to the “Indoor Fan Control” chapter.) as the graph shown below.2. PowerfulUnit is automatically operated in Quick Cooling (Fan speed "SHi": Refer to the "Indoor Fan Control” chapter.) in the initial 5minutes of the operation and after that, switched to Chilly Cooling according to the symmetrical areas.3. Low noise controlAt setting of Fan Speed: "AUTO" (Refer to the “Indoor Fan Control” chapter.), if room temperature reaches a settingtemperature, fan speed will be reduced for the fan noise reduction.4. Dew Condensation Prevention ControlThe maximum frequency for Indoor Unit is decided by the Dew Condensation Prevention Control according to elapsedoperating times. Condition: Indoor unit fan speed is "Me-" or less.CS-HE9DKE CS-HE12DKEMax. Frequency (A) (Hz) 35 54Max. Frequency (B) (Hz) 35 42Max. Frequency (C) (Hz) 30 37•••• Conditions resolutive−−−− When remote controller setting temperature or fan speed setting is changed:−−−− When 420 minutes elapsed:5. Forced Cooling OperationFan speed will be “Hi” (Refer to the “Indoor Fan Control” chapter.) when the units is operated at Forced operation mode.9.6.3. Dry OperationIn the cooling mode area, fan speed is the same as cooling operation mode. In the dry mode area, it is switched to "SLo". (Referto the “Indoor Fan Control” chapter.) In the Thermostat-OFF, fan stops 5.5 minutes and after that, operates at a speed of "SLo"(Refer to the “Indoor Fan Control” chapter.). (At manual fan speed) At automatic fan speed operation, fan operates repeatedlybetween 90-second stop and 20-second "SLo". At the beginning of unit operation and Thermostat-ON, fan stops 40 seconds.9.6.4. Heating Operation1. Hot Start and Cold DraftAt the beginning of unit operation, when indoor heat exchanger temperature is low, fan will be stopped. When the temperatureis getting high, the unit will be prevented from Cold Draft by increasing fan speed.2. Automatic fan speedAt automatic fan speed setting, when the heat exchanger temperature is getting high, the unit will be prevented from Cold draftby increasing fan speed as well as manual fan speed setting. In a fixed fan speed area, fan speed will be controlled to discharge29CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE