– 28 –CS-MA90KEInstallation InformationAttached accessoriesAccessories: Flaring piping kitCZ-4F5, 7, 10 ANSELECT THE BEST LOCATION• There should not be any heat source or steam near the unit.• There should not be any obstacles blocking the air circulation.• A place where air circulation in the room is good.• A place where drainage can be easily done.• A place where noise prevention is taken into consideration.• Do not install the unit near the door way.• Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.• Indoor unit of this room air conditioner shall be installed on the wall in a height of at least 2.3 m.• If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from thecondenser is not obstructed.• There should not be any animal or plant which could be affected by hot air discharged.• Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.• Do not place any obstacles which may cause a short circuit of the discharged air.• If piping length is over the rated length, additional refrigerant should be added as shown in the table.No.12345Accessories partInstallation plateInstallation plate fixing screwRemote controlBatteryAir purifying filterINDOOR UNITOUTDOOR UNITMODELMA70KEMA90KEMA120KEPiping sizeGas3/8"3/8"1/2"Liquid1/4"1/4"1/4"RatedLength777Max.Elevation(m)555Max.PipingLength(m)151515AdditionalRefrigerant(g/m)153030Qty.16122Accessories partDrain elbowClamping cover of pipingVinyl tapeVinyl tapeNo.6789Qty.1131