Time Delay Safety ControlStarting Current ControlAnti-Freezing ControlCompressor Reverse Rotation Protection ControlAutomatic Fan Speed Mode8.2. Soft Dry Mode Operation• The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, andthen Soft Dry operation will start.• During Soft Dry operation, the Indoor Fan will operate at low speed.• The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once Soft Dry operation is turnedoff, it stops for 6 minutes.• Once the compressor stops, it will not start for 3 minutes during Cooling operation.• Same as Starting Current Control for Cooling Mode operation.• Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressorstops.)• Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waitingis valid during compressor stops.)When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.• Fan speed off and on at Lo speed.• Deodorizing Control.35CS-MC95KE CU-MC145KE / CS-MC95KE CU-MC185KE / CS-MC95KE CU-3MC205KE / CS-MC125KE CU-MC245KE / CS-MC76KE / CS-MC126KE CU-MC196KE