8.8. Random Auto Restart Control• If there is a power failure, operation will be automatically restarted after 3 to 5 1/2 minutes when the power is resumed.It will start with previous operation mode and airflow direction.• Restart time is decided randomly using 4 parameter:-Intake air temperature, setting temperature, fan speed and Air Swing Blade position.• Auto Restart Control is not available when Timer or Sleep Mode is set.• This control can be omitted by open the circuit of JX1. (Refer Circuit Diagram)8.9. Indoor Fan Speed Control• Auto Fan Speed ControlWhen set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table.• Manual Fan Speed ControlBasic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button.Random Fan SpeedThe fan is turning at pattern A or B or C randomly, for an interval of 10” each during Random Fan Speed.39CS-MC95KE CU-MC145KE / CS-MC95KE CU-MC185KE / CS-MC95KE CU-3MC205KE / CS-MC125KE CU-MC245KE / CS-MC76KE / CS-MC126KE CU-MC196KE