3310. Installation Instruction10.1 Select the Best Location10.1.1 Indoor Unit Do not install the unit in excessive oil fume area such as kitchen, workshop and etc. There should not be any heat source or steam near the unit. There should not be any obstacles blocking the air circulation. A place where air circulation in the room is good. A place where drainage can be easily done. A place where noise prevention is taken into consideration. Do not install the unit near the door way. Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles. Recommended installation height for indoor unit shall be at least 2.5 m.10.1.2 Indoor Unit Installation DiagramdnebottonnoitnettAnoitceridgnipiPup drain hose(Front side)RightRearRightRightbottomLeftRear Left bottomLeftVinyl tapeRemote control holder fixing screws 6Remote control holder 5Remotecontrol 3• This illustration is for explanation purposes only.The indoor unit will actually face a different way.• Respective outdoor unit installation procedure shallrefer to instruction manual provided in the outdoorunit packaging.It is advisable to avoid more than 2 blockagedirections. For better ventilation & multiple-outdoor installation, please consult authorizeddealer/specialist.• Carry out insulation afterchecking for gas leaks andsecure with vinyl tape.Attaching the remote control holder to the wallInsulation of piping connections50 mmor more50 mmor more(Left and right are identical)Installation plate 1Sleeve ( )Bushing-Sleeve ( )Bend the pipe asclosely on the wall aspossible, but be carefulthat it doesn’t break.Saddle ( )Putty ( )(Gum Type Sealer)Vinyl tape (wide) ( )• Apply after carryingout a drainage test.• To carry out thedrainage test,remove the air filtersand pour water intothe heat exchanger.Installation parts youshould purchase ()