Time Delay Safety ControlStarting Current ControlAnti-Freezing ControlCompressor Reverse Rotation Protection ControlCompressor Protection ControlAutomatic Fan Speed Mode7.2. Soft Dry Mode Operation•••• The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, andthen Soft Dry operation will start.•••• During Soft Dry operation, the Indoor Fan will operate at Lo- speed.•••• The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once Soft Dry operation is turnedoff, it stops for 6 minutes.•••• Once the compressor stops, it will not start for 3 minutes during Cooling operation.•••• Same as Starting Current Control for Cooling Mode operation.•••• Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressorstops.)•••• Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waitingis valid during compressor stops.)•••• Same as Compressor Protection Control for Cooling Mode Operation.When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.•••• Fan speed rotates at Lo- speed.•••• Deodorizing Control.17CS-PW9CKE / CU-PW9CKE / CS-PW12CKE / CU-PW12CKEPanasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oywww.ilmalämpöpumput.com